Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Opt Express ; 32(3): 2942-2958, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-38297530

RESUMO

A method for spectral reflectance factor reconstruction based on wideband multi-illuminant imaging was proposed, using a programmable LED lighting system and modified Bare Bones Particle Swarm Optimization algorithms. From a set of 16 LEDs with different spectral power distributions, nine light sources with correlated color temperatures in the range of 1924 K - 15746 K, most of them daylight simulators, were generated. Samples from three color charts (X-Rite ColorChecker Digital SG, SCOCIE ScoColor paint chart, and SCOCIE ScoColor textile chart), were captured by a color industrial camera under the nine light sources, and used in sequence as training and/or testing colors. The spectral reconstruction models achieved under multi-illuminant imaging were trained and tested using the canonical Bare Bones Particle Swarm Optimization and its proposed modifications, along with six additional and commonly used algorithms. The impacts of different illuminants, illuminant combinations, algorithms, and training colors on reconstruction accuracy were studied comprehensively. The results indicated that training colors covering larger regions of color space give more accurate reconstructions of spectral reflectance factors, and combinations of two illuminants with a large difference of correlated color temperature achieve more than twice the accuracy of that under a single illuminant. Specifically, the average reconstruction error by the method proposed in this paper for patches from two color charts under A + D90 light sources was 0.94 and 1.08 CIEDE2000 color difference units. The results of the experiment also confirmed that some reconstruction algorithms are unsuitable for predicting spectral reflectance factors from multi-illuminant images due to the complexity of optimization problems and insufficient accuracy. The proposed reconstruction method has many advantages, such as being simple in operation, with no requirement of prior knowledge, and easy to implement in non-contact color measurement and color reproduction devices.

2.
Opt Express ; 28(7): 9123-9135, 2020 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-32225525

RESUMO

This work investigates the excitation of dense comb-like enhanced leaky mode resonance (eLMR) in tilted fiber Bragg grating (TFBG) integrated with indium tin oxide (ITO) nanocoating. The ITO overlay leads to a large reduction in mode loss and a great increase of propagation length for s-polarized leaky modes, which means the leaky modes become guided. The guidance of leaky modes enhances significantly the interaction with the core guided mode, which leads to the generation of strong dense comb-like eLMR. The results show that the ultra-narrow eLMR bands present promising sensing performance with an extended measurement range and provide advantages of high Q measurement over the case of surface plasmon resonance (SPR) and lossy mode resonance (LMR). The similarities and differences between the eLMR and SPR and LMR are also discussed. This study offers new opportunities to develop eLMR-based multifunctional fiber-optic devices with high performance.

3.
J Opt Soc Am A Opt Image Sci Vis ; 35(3): 397-405, 2018 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-29522041

RESUMO

This work presents a sensitive refractive index sensor based on the dual resonance of an excessively tilted long period fiber grating (Ex-TLPFG). The Ex-TLPFG is tuned to couple the guided core mode with only the polarization-degenerate cladding mode LP1,l, which consists of TE/TM0,l and HE2,l vector modes. It is found that the p-polarized LP1,lp mode exhibits a higher sensitivity than that of the s-polarized LP1,ls mode. An optimized sensitivity as high as 12182.9 nm/RIU is achieved for the p-polarized LP1,2p mode at the low refractive index region by tuning the initial resonance condition. The sensing performance is also evaluated through the power measurement method for a single resonance band. It is demonstrated that the improved sensitivity in this work for diameter-reduced Ex-TLPFG is much higher than that for the conventional LPFG based devices, which makes this sensing platform very attractive for a variety of index sensing applications.

4.
Opt Express ; 24(23): 26529-26535, 2016 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-27857386

RESUMO

We reported a compact self-cascaded KTA-OPO source for 2.6 µm coherent light generation. The OPO is driven in a diode end-pumped and Q-switched Nd:YVO4 laser cavity. Two OPO processes occurred in the same KTA crystal with non-critical phase matching. At an incident diode pump power of 8.7 W and a pulse repetition frequency of 60 kHz, the OPO can generate a maximum average output power of 445 mW at 2.59 µm. The slope efficiency was about 12.7%, and the power fluctuation was less than 8%. Therefore, the self-cascade OPO based on KTA offers a promise scheme for the rugged and compact mid-infrared 2.6 µm laser generation.

5.
Opt Express ; 24(13): 14066-78, 2016 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-27410567

RESUMO

For the correlated color temperature (CCT) of a light source to be estimated, a nonlinear optimization problem must be solved. In all previous methods available to compute CCT, the objective function has only been approximated, and their predictions have achieved limited accuracy. For example, different unacceptable CCT values have been predicted for light sources located on the same isotemperature line. In this paper, we propose to compute CCT using the Newton method, which requires the first and second derivatives of the objective function. Following the current recommendation by the International Commission on Illumination (CIE) for the computation of tristimulus values (summations at 1 nm steps from 360 nm to 830 nm), the objective function and its first and second derivatives are explicitly given and used in our computations. Comprehensive tests demonstrate that the proposed method, together with an initial estimation of CCT using Robertson's method [J. Opt. Soc. Am. 58, 1528-1535 (1968)], gives highly accurate predictions below 0.0012 K for light sources with CCTs ranging from 500 K to 106 K.

6.
Anal Chim Acta ; 858: 16-23, 2015 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-25597797

RESUMO

The successive projections algorithm (SPA) is widely used to select variables for multiple linear regression (MLR) modeling. However, SPA used only once may not obtain all the useful information of the full spectra, because the number of selected variables cannot exceed the number of calibration samples in the SPA algorithm. Therefore, the SPA-MLR method risks the loss of useful information. To make a full use of the useful information in the spectra, a new method named "consensus SPA-MLR" (C-SPA-MLR) is proposed herein. This method is the combination of consensus strategy and SPA-MLR method. In the C-SPA-MLR method, SPA-MLR is used to construct member models with different subsets of variables, which are selected from the remaining variables iteratively. A consensus prediction is obtained by combining the predictions of the member models. The proposed method is evaluated by analyzing the near infrared (NIR) spectra of corn and diesel. The results of C-SPA-MLR method showed a better prediction performance compared with the SPA-MLR and full-spectra PLS methods. Moreover, these results could serve as a reference for combination the consensus strategy and other variable selection methods when analyzing NIR spectra and other spectroscopic techniques.


Assuntos
Algoritmos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Conjuntos de Dados como Assunto , Gasolina/análise , Modelos Lineares , Software , Espectroscopia de Luz Próxima ao Infravermelho/estatística & dados numéricos , Zea mays/química
7.
Opt Express ; 22(22): 27425-36, 2014 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-25401891

RESUMO

An analytical model of vector formalism is proposed to investigate the diffraction of high numerical aperture subwavelength circular binary phase Fresnel zone plate (FZP). In the proposed model, the scattering on the FZP's surface, reflection and refraction within groove zones are considered and diffraction fields are calculated using the vector Rayleigh-Sommerfeld integral. The numerical results obtained by the proposed phase thick FZP (TFZP) model show a good agreement with those obtained by the finite-difference time-domain (FDTD) method within the effective extent of etch depth. The optimal etch depths predicted by both methods are approximately equal. The analytical TFZP model is very useful for designing a phase and hybrid amplitude-phase FZP with high-NA and short focal length.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...